HP Elite SMB Partner

HP Elite SMB PartnerHP E3500 yl Switch Series

Most advanced intelligent edge capability in both chassis (6-slot and 12-slot) and stackable (24-port and 48-port) from factors

HP E3500 yl Switch Series

HP ProCurve Products
HP ProCurve Switches
HP E3500-24 Switch #J9470A#ABA
List Price: $2,449.00
Our Price: $1,794.00
HP E3500-24-PoE Switch #J9471A#ABA
List Price: $3,099.00
Our Price: $2,270.00
HP E3500-24G-PoE yl Switch #J8692A#ABA
List Price: $3,999.00
Our Price: $2,512.00
HP E3500-24G-PoE+ yl Switch #J9310A#ABA
List Price: $3,899.00
Our Price: $2,856.00
HP E3500-48 Switch #J9472A#ABA
List Price: $4,099.00
Our Price: $3,003.00
HP E3500-48-PoE Switch #J9473A#ABA
List Price: $5,299.00
Our Price: $3,882.00
HP E3500-48G-PoE yl Switch #J8693A#ABA
List Price: $7,199.00
Our Price: $5,274.00
HP E3500-48G-PoE+ yl Switch #J9311A#ABA
List Price: $7,199.00
Our Price: $5,274.00

Click here to jump to more pricing!

Overview:

The HP E3500 Switch Series consists of the most advanced intelligent edge switches in the HP Networking product line. The E3500 series includes 24-port and 48-port fixed-port switches. The foundation for all these switches is a purpose-built, programmable ProVision ASIC that allows the most demanding networking features, such as Quality of Service (QoS) and security, to be implemented in a scalable yet granular fashion. With a variety of Gigabit and 10/100 interfaces; integrated PoE+, PoE, and non-PoE options; and versatile 10-GbE connectivity (CX4, X2, and SFP+) on Gigabit switches, the E3500 switches offer excellent investment protection, flexibility, and scalability, as well as ease of deployment, operation, and maintenance.

  • Advanced access layer and small distribution
  • Enterprise-class performance and security
  • Intelligent Edge feature set with L2 to L4 support
  • Scalable 10/100/1000 PoE+ and 10/100 PoE
  • Unified core-to-edge ProVision software

HP E3500 yl Switch Series Models:


Features and Benefits:

Quality of Service (QoS)

  • Advanced classifier-based QoS — classifies traffic using multiple match criteria based on Layer 2, 3, and 4 information; applies QoS policies such as setting priority level and rate limit to selected traffic on a per-port or per-VLAN basis
  • Layer 4 prioritization — enables prioritization based on TCP/UDP port numbers
  • Traffic prioritization — allows real-time traffic classification into eight priority levels mapped to eight queues
  • Bandwidth shaping
    • Port-based rate limiting — provides per-port ingress-/egress-enforced maximum bandwidth
    • Classifier-based rate limiting — uses access control list (ACL) to enforce maximum bandwidth for ingress traffic on each port
    • Guaranteed minimum — provides per-port, per-queue egress-based guaranteed minimum bandwidth
  • Class of service (CoS) — sets the IEEE 802.1p priority tag based on IP address, IP Type of Service (ToS), Layer 3 protocol, TCP/UDP port number, source port, and DiffServ

Management

  • Remote Intelligent Mirroring — mirrors selected ingress/egress traffic based on ACL, port, MAC address, or VLAN to a local or remote HP E8200 zl, E6600, E6200 yl, E5400 zl, or E3500 switch anywhere on the network
  • RMON, XRMON, and sFlow v5 — provide advanced monitoring and reporting capabilities for statistics, history, alarms, and events
  • IEEE 802.1AB Link Layer Discovery Protocol (LLDP) — automated device discovery protocol provides easy mapping by network management applications
  • Uni-Directional Link Detection (UDLD) — monitors cable between two switches and shuts down the ports on both ends if the cable is broken, turning the bi-directional link into uni-directional; this prevents network problems such as loops
  • Management simplicity — provides HP E-Series-common networking features and CLI implementation (common across HP E8200 zl, E6600, E6200 yl, E5400 zl, and E3500 switches)
  • Command authorization — leverages RADIUS to link a custom list of CLI commands to an individual network administrator's login; also provides an audit trail
  • Friendly port names — allow assignment of descriptive names to ports
  • Dual flash images — provide independent primary and secondary operating system files for backup while upgrading
  • Multiple configuration files — can be stored to the flash image

Connectivity

  • IPv6
    • IPv6 host — enables switches to be managed and deployed at the IPv6 network's edge
    • Dual stack (IPv4 and IPv6) — transitions from IPv4 to IPv6, supporting connectivity for both protocols
    • MLD snooping — forwards IPv6 multicast traffic to the appropriate interface
    • IPv6 ACL/QoS — supports ACL and QoS for IPv6 network traffic, preventing traffic flooding
    • IPv6 routing — supports static and OSPFv3 routing protocols
  • IEEE 802.3af Power over Ethernet (PoE) — provides up to 15.4 W per port to IEEE 802.3af-compliant PoE-powered devices such as IP phones, wireless access points, and security cameras
  • IEEE 802.3at Power Over Ethernet Plus (PoE+) — provides up to 30 W per port to IEEE 802.3 for PoE-/PoE+-powered devices such as video IP phones, IEEE 802.11n wireless access points, and advanced pan/zoom/tilt security cameras
  • Prestandard PoE support — detects and provides power to prestandard PoE devices; see list of supported devices in the product FAQs at www.hp.com/networking
  • Jumbo frames — on Gigabit and 10-Gigabit ports, they allow high-performance remote backup and disaster recovery services
  • Auto-MDIX — automatically adjusts for straight-through or crossover cables on all 10/100 and 10/100/1000 ports

Performance

  • High-speed/capacity architecture — up to 153.6 Gbps crossbar switching fabric provides intra- and inter-module switching with up to 111.5 million pps throughput on the purpose-built ProVision ASICs
  • Selectable queue configurations — allow you to increase performance by selecting the number of queues and associated memory buffering that best meet the requirements of your network applications

Resiliency and high availability

  • Virtual Router Redundancy Protocol (requires Premium License) — allows groups of two routers to dynamically back each other up to create highly available routed environments
  • IEEE 802.1s Multiple Spanning Tree Protocol — provides high link availability in multiple VLAN environments by allowing multiple spanning trees; encompasses IEEE 802.1D Spanning Tree Protocol and IEEE 802.1w Rapid Spanning Tree Protocol
  • IEEE 802.3ad Link Aggregation Control Protocol (LACP) and HP port trunking — support up to 60 trunks, each with up to 8 links (ports) per trunk
  • Distributed trunking — enables loop-free and redundant network topology without using Spanning Tree Protocol; allows a server or switch to connect to two switches using one logical trunk for redundancy and load sharing

Layer 2 switching

  • IEEE 802.1ad QinQ (requires Premium License) — increases the scalability of an Ethernet network by providing a hierarchical structure; connects multiple LANs on high-speed campus or metro network
  • HP's switch meshing — dynamically load balances across multiple active redundant links to increase available aggregate bandwidth
  • VLAN support and tagging — supports the IEEE 802.1Q standard and 2048 VLANs simultaneously
  • IEEE 802.1v protocol VLANs — isolate select non-IPv4 protocols automatically into their own VLANs
  • GARP VLAN Registration Protocol (GVRP) — allows automatic learning and dynamic assignment of VLANs

Layer 3 services

  • User Datagram Protocol (UDP) helper function — allows UDP broadcasts to be directed across router interfaces to specific IP unicast or subnet broadcast addresses and prevents server spoofing for UDP services such as DHCP
  • Loopback interface address — defines an address in Routing Information Protocol (RIP) and OSPF that can always be reachable, improving diagnostic capability
  • Route maps — provide more control during route redistribution; allow filtering and altering of route metrics
Layer 3 routing
  • Static IP routing — provides manually configured routing for both IPv4 and IPv6 networks
  • Routing Information Protocol (RIP) — provides RIPv1 and RIPv2 routing
  • OSPF (requires Premium License) — provides OSPFv2 for IPv4 routing and OSPFv3 for IPv6 routing
Security
  • Access control lists (ACLs) — provide filtering based on the IP field, source/destination IP address/subnet, and source/destination TCP/UDP port number on a per-VLAN or per-port basis
  • Multiple user authentication methods
    • IEEE 802.1X users per port — provides authentication of multiple IEEE 802.1X users per port; prevents user "piggybacking" on another user's IEEE 802.1X authentication
    • Web-based authentication — authenticates from Web browser for clients that do not support IEEE 802.1X supplicant; customized remediation can be processed on an external Web server
    • MAC-based authentication — client is authenticated with the RADIUS server based on client's MAC address
    • Concurrent IEEE 802.1X, Web, and MAC authentication schemes per port — switch port will accept up to 32 sessions of IEEE 802.1X, Web, and MAC authentications
  • Virus throttling — detects traffic patterns typical of WORM-type viruses and either throttles or entirely prevents the virus from spreading across the routed VLANs or bridged interfaces, without requiring external appliances
  • DHCP protection — blocks DHCP packets from unauthorized DHCP servers, preventing denial-of-service attacks
  • Secure management access — securely encrypts all access methods (CLI, GUI, or MIB) through SSHv2, SSL, and/or SNMPv3
  • USB Secure Autorun (requires HP PCM+) — deploys, diagnoses, and updates switch using a USB flash drive; works with a secure credential to prevent tampering
  • Switch CPU protection — provides automatic protection against malicious network traffic trying to shut down the switch
  • ICMP throttling — defeats ICMP denial-of-service attacks by enabling any switch port to automatically throttle ICMP traffic
  • Identity-driven ACL — enables implementation of a highly granular and flexible access security policy and VLAN assignment specific to each authenticated network user
  • STP BPDU port protection — blocks Bridge Protocol Data Units (BPDUs) on ports that do not require BPDUs, preventing forged BPDU attacks
  • Dynamic IP lockdown — works with DHCP protection to block traffic from unauthorized hosts, preventing IP source address spoofing
  • Dynamic ARP protection — blocks ARP broadcasts from unauthorized hosts, preventing eavesdropping or theft of network data
  • STP Root Guard — protects root bridge from malicious attack or configuration mistakes
  • Detection of malicious attacks — monitors 10 types of network traffic and sends a warning when an anomaly that potentially can be caused by malicious attacks is detected
  • Port security — allows access only to specified MAC addresses, which can be learned or specified by the administrator
  • MAC address lockout — prevents particular configured MAC addresses from connecting to the network
  • Source-port filtering — allows only specified ports to communicate with each other
  • RADIUS/TACACS+ — eases switch management security administration by using a password authentication server
  • Secure Shell (SSHv2) — encrypts all transmitted data for secure, remote command-line interface (CLI) access over IP networks
  • Secure Sockets Layer (SSL) — encrypts all HTTP traffic, allowing secure access to the browser-based management GUI in the switch
  • Secure File Transfer Protocol (FTP) — allows secure file transfer to and from the switch; protects against unwanted file downloads or unauthorized copying of switch configuration file
  • Management Interface Wizard — helps ensure that management interfaces such as SNMP, telnet, SSH, SSL, Web, and USB are secured to the desired level
  • Switch management logon security — can require either RADIUS or TACACS+ authentication for secure switch CLI logon
  • Security banner — displays a customized security policy when users log in to the switch

Convergence

  • IP multicast routing (requires Premium License) — includes PIM Sparse and Dense modes to route IP multicast traffic
  • IP multicast snooping (data-driven IGMP) — automatically prevents flooding of IP multicast traffic
  • LLDP-MED (Media Endpoint Discovery) — is a standard extension of LLDP that stores values for parameters such as QoS and VLAN to automatically configure network devices such as IP phones
  • RADIUS VLAN for voice — uses standard RADIUS attribute and LLDP-MED to automatically configure VLAN for IP phones
  • PoE allocations — support multiple methods (automatic, IEEE 802.3af class, LLDP-MED, or user specified) to allocate PoE power for more efficient energy savings

Warranty and support

  • 1-year warranty — with advance replacement and 10-calendar-day delivery (available in most countries)
  • Electronic and telephone support — limited electronic and telephone support is available from HP; refer to www.hp.com/networking/warranty for details on the support provided and the period during which support is available
  • Software releases — refer to www.hp.com/networking/warranty for details on the software releases provided and the period during which software releases are available for your product(s)

Specifications:

  E3500-24 (J9470A) E3500-48 (J9472A)
  E3500-24 Switch (J9470A) E3500-48 Switch (J9472A)
Port
 
  • 44 RJ-45 autosensing 10/100 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX)
  • Media Type: Auto-MDIX
  • Duplex: half or full
  • 4 dual-personality ports
  • each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an open mini-GBIC slot (for use with mini-GBIC transceivers)
  • 1 RS-232C DB-9 console port
  • 20 RJ-45 autosensing 10/100 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX)
  • Media Type: Auto-MDIX
  • Duplex: half or full
  • 4 dual-personality ports
  • each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
  • 1 RS-232C DB-9 console port
Physical characteristics
Dimensions 15.43(d) x 17.44(w) x 1.73(h) in.
(39.2 x 44.3 x 4.4 cm) (1U height)
16.93(d) x 17.44(w) x 1.73(h) in.
(43.0 x 44.3 x 4.4 cm) (1U height)
Weight 11.9 lb. (5.4 kg) 13.45 lb. (6.1 kg)
Memory and processor
  Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash Mb, 128 MB compact flash, 256 MB DDR SDRAM
Mounting
  Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Performance
100 Mb Latency < 3.4 µs (LIFO 64-byte packets) < 3.4 µs (FIFO 64-byte packets)
1000 Mb Latency < 2.9 µs (LIFO 64-byte packets) < 2.4 µs (FIFO 64-byte packets)
Throughput Up to 8.9 million pps (64-byte packets) Up to 12.5 million pps (64-byte packets)
Routing/Switching capacity 12 Gbps 16.8 Gbps
Routing table size 10000 entries 10000 entries
MAC address table size 64000 entries 64000 entries
Environment
Operating temperature 32°F to 131°F (0°C to 55°C) 32°F to 131°F (0°C to 55°C)
Operating relative humidity 15% to 95% @ 104°F (40°C), noncondensing 15% to 95% @ 104°F (40°C), noncondensing
Non-Operating temperature -40°F to 158°F (-40°C to 70°C) -40°F to 158°F (-40°C to 70°C)
Non-Operating relative humidity 15% to 95% @ 149°F (65°C), noncondensing 15% to 95% @ 149°F (65°C), noncondensing
Altitude up to 15,000 ft. (4.6 km) up to 15,000 ft. (4.6 km)
Acoustic Power: 53.1 dB, Pressure: 42.6 dB ISO 7779, ISO 9296 Power: 55.8 dB, Pressure: 43.5 dB ISO 7779, ISO 9296
Electrical characteristics
Description The switch automatically adjusts to any voltage between 100-127 and 200-240 volts with either 50 or 60 Hz The switch automatically adjusts to any voltage between 100-127 and 200-240 volts with either 50 or 60 Hz
Maximum heat dissipation 268 BTU/hr (282.8 kJ/hr) 465 BTU/hr (490.58 kJ/hr)
Voltage 100-127/200-240 VAC 100-127/200-240 VAC
Current 1.1/0.6 A 1.6/0.8 A
Idle power 68.2 W 96 W
Maximum power rating 78.7 W 136.2 W
Frequency 50/60 Hz 50/60 Hz
Notes Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
  CSA 22.2 No. 60950UL 60950IEC 60950EN 60950 EN 60950/IEC 60950CAN/CSA 22.2 No. 60950UL 60950IEC 60950
Notes
  When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required. When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
  E3500-24-PoE (J9471A) E3500-24G-PoE yl (J8692A) E3500-24G-PoE+ yl (J9310A)
  E3500-24-PoE Switch (J9471A) E3500-24G-PoE yl Switch (J8692A) E3500-24G-PoE+ yl Switch (J9310A)
Port
 
  • 20 RJ-45 autosensing 10/100 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX)
  • Media Type: Auto-MDIX
  • Duplex: half or full
  • 4 dual-personality ports
  • each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
  • 1 RS-232C DB-9 console port
  • 1 open module slot
  • 20 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T)
  • Media Type: Auto-MDIX
  • Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only
  • 4 dual-personality ports
  • each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an open mini-GBIC slot (for use with mini-GBIC transceivers)
  • Supports a maximum of 4 10-GbE ports, with optional module
  • 1 open module slot
  • 20 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T)
  • Media Type: Auto-MDIX
  • Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only
  • 1 RJ-45 serial console port
  • 4 dual-personality ports
  • each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an open mini-GBIC slot (for use with mini-GBIC transceivers)
  • Supports a maximum of 4 10-GbE ports
Physical characteristics
Dimensions 15.43(d) x 17.44(w) x 1.73(h) in.
(39.2 x 44.3 x 4.4 cm)
(1U height)
15.43(d) x 17.44(w) x 1.73(h) in.
(39.2 x 44.3 x 4.4 cm)
(1U height)
15.43(d) x 17.44(w) x 1.73(h) in.
(39.2 x 44.3 x 4.4 cm)
(1U height)
Weight 13.23 lb. (6 kg) 14.11 lb. (6.4 kg) 13.86 lb. (6.29 kg)
Memory and processor
10G Module - ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM
Management Module Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM
Mounting
  Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Performance
100 Mb Latency < 3.4 µs (LIFO 64-byte packets) - -
1000 Mb Latency < 2.9 µs (LIFO 64-byte packets) < 3.4 µs (FIFO 64-byte packets) < 3.4 µs (FIFO 64-byte packets)
10 Gbps Latency - < 2.1 µs (FIFO 64-byte packets) < 2.1 µs (FIFO 64-byte packets)
Throughput Up to 8.9 million pps (64-byte packets) Up to 75.7 million pps Up to 75.7 million pps
Routing/Switching capacity 12 Gbps 101.8 Gbps 101.8 Gbps
Switch fabric speed - 105.6 Gbps 105.6 Gbps
Routing table size 10000 entries 10000 entries 10000 entries
MAC address table size 64000 entries 64000 entries 64000 entries
Environment
Operating temperature 32°F to 131°F (0°C to 55°C) 32°F to 131°F (0°C to 55°C); 32°F to 104°F (40°C) when used with any X2 10-GbE 32°F to 131°F (0°C to 55°C); 32°F to 104°F (40°C) when used with any X2 10-GbE
Operating relative humidity 15% to 95% @ 104°F (40°C), noncondensing 15% to 95% @ 104°F (40°C), noncondensing 15% to 95% @ 104°F (40°C), noncondensing
Non-Operating temperature -40°F to 158°F (-40°C to 70°C) -40°F to 158°F (-40°C to 70°C) -40°F to 158°F (-40°C to 70°C)
Non-Operating relative humidity 15% to 90% @ 149°F (65°C), noncondensing 15% to 90% @ 149°F (65°C), noncondensing 15% to 90% @ 149°F (65°C), noncondensing
Altitude Up to 15,000 ft. (4.6 km) Up to 15,000 ft. (4.6 km) Up to 15,000 ft. (4.6 km)
Acoustic Power: 55.1 dB, Pressure: 44.8 dB ISO 7779, ISO 9296 Power: 55.1 dB, Pressure: 44.8 dB ISO 7779, ISO 9296 Power: 57.0 dB, Pressure: 40.5 dB ISO 7779, ISO 9296
Electrical characteristics
Description The switch automatically adjusts to any voltage between 100-120 and 200-240 volts and either 50 or 60 Hz The switch automatically adjusts to any voltage between 100-120 and 200-240 volts and either 50 or 60 Hz The switch automatically adjusts to any voltage between 100-120 and 200-240 volts and either 50 or 60 Hz
Maximum heat dissipation 435 BTU/hr (458.92 kJ/hr) 865 BTU/hr (912.9 kJ/hr) 865 BTU/hr (912.9 kJ/hr)
Voltage 100-127/200-240 VAC 100-127/200-240 VAC 100-127/200-240 VAC
Current 6.6/3.0 A 10.0/5.0 A 6.6/3.0 A
Idle power 91 W 98 W 94 W
Maximum power rating 497 W 623 W 616 W
PoE power 398 W 398 W 398 W
Frequency 50/60 Hz 50/60 Hz 50/60 Hz
Notes Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
The amount of PoE power delivered is dependent on the number and type of power supplies connected. The switches offer optional external power supplies (EPS) for maximum PoE power.
Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
The amount of PoE power delivered is dependent on the number and type of power supplies connected. The switches offer optional external power supplies (EPS) for maximum PoE power.
Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
The amount of PoE power delivered is dependent on the number and type of power supplies connected. The switches offer optional external power supplies (EPS) for maximum PoE power.
Safety
  EN 60950/IEC 60950CAN/CSA 22.2 No. 60950EN 60825UL 60950 CSA 22.2 No. 60950UL 60950IEC 60950EN 60950 CSA 22.2 No. 60950UL 60950IEC 60950EN 60950
Notes
  When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required. When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required. When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
  E3500-48-PoE (J9473A) E3500-48G-PoE yl (J8693A) E3500-48G-PoE+ yl (J9311A)
  E3500-48-PoE Switch (J9473A) E3500-48G-PoE yl Switch (J8693A) E3500-48G-PoE+ yl Switch (J9311A)
Port
 
  • 44 RJ-45 autosensing 10/100 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX)
  • Media Type: Auto-MDIX
  • Duplex: half or full
  • 4 dual-personality ports
  • each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an open mini-GBIC slot (for use with mini-GBIC transceivers)
  • 1 RS-232C DB-9 console port
  • 1 open module slot
  • 44 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T)
  • Media Type: Auto-MDIX
  • Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only
  • 4 dual-personality ports
  • each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an open mini-GBIC slot (for use with mini-GBIC transceivers)
  • Supports a maximum of 4 10-GbE ports, with optional module
  • 1 open module slot
  • 44 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T)
  • Media Type: Auto-MDIX
  • Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only
  • 1 RJ-45 serial console port
  • 4 dual-personality ports
  • each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an open mini-GBIC slot (for use with mini-GBIC transceivers)
  • Supports a maximum of 4 10-GbE ports
Physical characteristics
Dimensions 16.93(d) x 17.44(w) x 1.73(h) in.
(43.0 x 44.3 x 4.4 cm)
(1U height)
16.93(d) x 17.44(w) x 1.73(h) in.
(43.0 x 44.3 x 4.4 cm)
(1U height)
16.93(d) x 17.44(w) x 1.73(h) in.
(43.0 x 44.3 x 4.4 cm)
(1U height)
Weight 14.99 lb. (6.8 kg) 16.09 lb. (7.3 kg) 15.54 lb. (7.05 kg)
Memory and processor
10G Module - ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM
Management Module Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash Mb, 128 MB compact flash, 256 MB DDR SDRAM Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash Mb, 128 MB compact flash, 256 MB DDR SDRAM
Mounting
  Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Performance
100 Mb Latency < 3.4 µs (LIFO 64-byte packets) - -
1000 Mb Latency < 2.9 µs (LIFO 64-byte packets) < 3.4 µs (FIFO 64-byte packets) < 3.4 µs (FIFO 64-byte packets)
10 Gbps Latency - < 2.1 µs (FIFO 64-byte packets) < 2.1 µs (FIFO 64-byte packets)
Throughput Up to 12.5 million pps (64-byte packets) Up to 111.5 million pps Up to 111.5 million pps
Routing/Switching capacity 16.8 Gbps 149.8 Gbps 149.8 Gbps
Switch fabric speed - 153.6 Gbps 153.6 Gbps
Routing table size 10000 entries 10000 entries 10000 entries
MAC address table size 64000 entries 64000 entries 64000 entries
Environment
Operating temperature 32°F to 131°F (0°C to 55°C) 32°F to 131°F (0°C to 55°C); 32°F to 104°F (40°C) when used with any X2 10-GbE 32°F to 131°F (0°C to 55°C); 32°F to 104°F (40°C) when used with any SFP+ 10-GbE
Operating relative humidity 15% to 95% @ 104°F (40°C), noncondensing 15% to 95% @ 104°F (40°C), noncondensing 15% to 95% @ 104°F (40°C), noncondensing
Non-Operating temperature -40°F to 158°F (-40°C to 70°C) -40°F to 158°F (-40°C to 70°C) -40°F to 158°F (-40°C to 70°C)
Non-Operating relative humidity 15% to 95% @ 149°F (65°C), noncondensing 15% to 95% @ 149°F (65°C), noncondensing 15% to 95% @ 149°F (65°C), noncondensing
Altitude Up to 15,000 ft. (4.6 km) Up to 15,000 ft. (4.6 km) Up to 15,000 ft. (4.6 km)
Acoustic Power: 55.6 dB, Pressure: 45.3 dB ISO 7779, ISO 9296 Power: 55.6 dB, Pressure: 45.3 dB ISO 7779, ISO 9296 Power: 58.0 dB, Pressure: 42.0 dB ISO 7779, ISO 9296
Electrical characteristics
Description The switch automatically adjusts to any voltage between 100-127 and 200-240 volts with either 50 or 60 Hz The switch automatically adjusts to any voltage between 100-127 and 200-240 volts with either 50 or 60 Hz The switch automatically adjusts to any voltage between 100-127 and 200-240 volts with either 50 or 60 Hz
Maximum heat dissipation 611 BTU/hr (644.6 kJ/hr) 1144 BTU/hr (1206.9 kJ/hr) 1144 BTU/hr (1206.9 kJ/hr)
Voltage 100-127/200-240 VAC 100-127/200-240 VAC 100-127/200-240 VAC
Current 7.3/3.3 A 10.0/5.0 A 7.3/3.3 A
Idle power 133.2 W 142 W 132 W
Maximum power rating 548.8 W 705 W 638 W
PoE power 398 W 398 W 398 W
Frequency 50/60 Hz 50/60 Hz 50/60 Hz
Notes Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
The amount of PoE power delivered is dependent on the number and type of power supplies connected. The switches offer optional external power supplies (EPS) for maximum PoE power.
Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
The amount of PoE power delivered is dependent on the number and type of power supplies connected. The switches offer optional external power supplies (EPS) for maximum PoE power.
Idle power is the actual power consumption of the device with no ports connected.
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
The amount of PoE power delivered is dependent on the number and type of power supplies connected. The switches offer optional external power supplies (EPS) for maximum PoE power.
Safety
  EN 60950/IEC 60950CAN/CSA 22.2 No. 60950UL 60950IEC 60950 CSA 22.2 No. 60950UL 60950IEC 60950EN 60950 CSA 22.2 No. 60950UL 60950IEC 60950EN 60950
Notes
  When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required. When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required. When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.

Additional Features:

(Applies to All Switches in Series)

General Specifications
Emissions
  • FCC Class A
  • VCCI Class A
  • EN 55022/CISPR 22 Class A

Management

  • HP PCM+
  • HP PCM (included)
  • Command-line interface
  • Web browser
  • Configuration menu
  • Out-of-band management (serial RS-232C)
Immunity
  • EN: EN 55024, CISPR 24
  • ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD
  • Radiated: IEC 61000-4-3; 3 V/m
  • EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
  • Surge: IEC 61000-4-5; 1 kV/2 kV AC
  • Conducted: IEC 61000-4-6; 3 V
  • Power frequency magnetic field: IEC 61000-4-8; 1 A/m, 50 or 60 Hz
  • Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
  • Harmonics: EN 61000-3-2, IEC 61000-3-2
  • Flicker: EN 61000-3-3, IEC 61000-3-3
Standards and Protocols
Device management
  • RFC 1591 DNS (client)
  • HTML and telnet management

General protocols

  • IEEE 802.1ad Q-in-Q
  • IEEE 802.1AX-2008 Link Aggregation
  • IEEE 802.1D MAC Bridges
  • IEEE 802.1p Priority
  • IEEE 802.1Q VLANs
  • IEEE 802.1s Multiple Spanning Trees
  • IEEE 802.1v VLAN classification by Protocol and Port
  • IEEE 802.1w Rapid Reconfiguration of Spanning Tree
  • IEEE 802.3ad Link Aggregation Control Protocol (LACP)
  • IEEE 802.3af Power over Ethernet
  • IEEE 802.3x Flow Control
  • RFC 768 UDP
  • RFC 783 TFTP Protocol (revision 2)
  • RFC 792 ICMP
  • RFC 793 TCP
  • RFC 826 ARP
  • RFC 854 TELNET
  • RFC 868 Time Protocol
  • RFC 951 BOOTP
  • RFC 1058 RIPv1
  • RFC 1350 TFTP Protocol (revision 2)
  • RFC 1519 CIDR
  • RFC 1542 BOOTP Extensions
  • RFC 2030 Simple Network Time Protocol (SNTP) v4
  • RFC 2131 DHCP
  • RFC 2453 RIPv2
  • RFC 2548 (MS-RAS-Vendor only)
  • RFC 3046 DHCP Relay Agent Information Option
  • RFC 3576 Ext to RADIUS (CoA only)
  • RFC 3768 VRRP
  • RFC 4675 RADIUS VLAN & Priority
  • UDLD (Uni-directional Link Detection)

IP multicast

  • RFC 3376 IGMPv3 (host joins only)
  • RFC 3973 Draft 2 PIM Dense Mode
  • RFC 4601 Draft 10 PIM Sparse Mode

IPv6

  • RFC 1981 IPv6 Path MTU Discovery
  • RFC 2375 IPv6 Multicast Address Assignments
  • RFC 2460 IPv6 Specification
  • RFC 2464 Transmission of IPv6 over Ethernet Networks
  • RFC 2710 Multicast Listener Discovery (MLD) for IPv6
  • RFC 2925 Definitions of Managed Objects for Remote Ping, Traceroute, and Lookup Operations (Ping only)
  • RFC 3019 MLDv1 MIB
  • RFC 3315 DHCPv6 (client and relay)
  • RFC 3484 Default Address Selection for IPv6
  • RFC 3587 IPv6 Global Unicast Address Format
  • RFC 3596 DNS Extension for IPv6
  • RFC 3810 MLDv2 (host joins only)
  • RFC 4022 MIB for TCP
  • RFC 4113 MIB for UDP
  • RFC 4251 SSHv6 Architecture
  • RFC 4252 SSHv6 Authentication
  • RFC 4253 SSHv6 Transport Layer
  • RFC 4254 SSHv6 Connection
  • RFC 4291 IP Version 6 Addressing Architecture
  • RFC 4293 MIB for IP
  • RFC 4294 IPv6 Node Requirements
  • RFC 4419 Key Exchange for SSH
  • RFC 4443 ICMPv6
  • RFC 4541 IGMP & MLD Snooping Switch
  • RFC 4861 IPv6 Neighbor Discovery
  • RFC 4862 IPv6 Stateless Address Auto-configuration
  • RFC 5095 Deprecation of Type 0 Routing Headers in IPv6
  • RFC 5340 OSPFv3 for IPv6
  • RFC 5453 Reserved IPv6 Interface Identifiers
  • RFC 5722 Handling of Overlapping IPv6 Fragments
MIBs
  • RFC 1213 MIB II
  • RFC 1493 Bridge MIB
  • RFC 1724 RIPv2 MIB
  • RFC 1850 OSPFv2 MIB
  • RFC 2021 RMONv2 MIB
  • RFC 2096 IP Forwarding Table MIB
  • RFC 2613 SMON MIB
  • RFC 2618 RADIUS Client MIB
  • RFC 2620 RADIUS Accounting MIB
  • RFC 2665 Ethernet-Like-MIB
  • RFC 2668 802.3 MAU MIB
  • RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
  • RFC 2737 Entity MIB (Version 2)
  • RFC 2787 VRRP MIB
  • RFC 2863 The Interfaces Group MIB
  • RFC 2925 Ping MIB

Network management

  • IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
  • RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
  • RFC 3176 sFlow
  • ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
  • SNMPv1/v2c/v3
  • XRMON

OSPF

  • RFC 2328 OSPFv2
  • RFC 3101 OSPF NSSA
  • RFC 5340 OSPFv3 for IPv6

QoS/CoS

  • RFC 2474 DiffServ Precedence, including 8 queues/port
  • RFC 2597 DiffServ Assured Forwarding (AF)
  • RFC 2598 DiffServ Expedited Forwarding (EF)

Security

  • IEEE 802.1X Port Based Network Access Control
  • RFC 1492 TACACS+
  • RFC 2865 RADIUS (client only)
  • RFC 2866 RADIUS Accounting
  • Secure Sockets Layer (SSL)
  • SSHv1/SSHv2 Secure Shell

Services and Support:

HP Care Packs for HP Networking

HP E3500 24-port Switch Series (J9470A, J9471A, J8692A, J9310A)

  • 3-year, 4-hour onsite, 13x5 coverage for hardware (U2855E)
  • 3-year, 4-hour onsite, 24x7 coverage for hardware (U2856E)
  • 3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 SW phone support and SW updates (U6304E)
  • 3-year, 24x7 SW phone support, software updates (UE262E)
  • Installation with minimum configuration, system-based pricing (U4826E)
  • Installation with HP-provided configuration, system-based pricing (U4830E)
  • 4-year, 4-hour onsite, 13x5 coverage for hardware (UR868E)
  • 4-year, 4-hour onsite, 24x7 coverage for hardware (UR869E)
  • 4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR870E)
  • 4-year, 24x7 SW phone support, software updates (UR871E)
  • 5-year, 4-hour onsite, 13x5 coverage for hardware (UR872E)
  • 5-year, 4-hour onsite, 24x7 coverage for hardware (UR873E)
  • 5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR874E)
  • 5-year, 24x7 SW phone support, software updates (UR875E)
  • 3 Yr 6 hr Call-to-Repair Onsite (UW356E)
  • 4 Yr 6 hr Call-to-Repair Onsite (UW357E)
  • 5 Yr 6 hr Call-to-Repair Onsite (UW358E)

HP E3500 48-port Switch Series (J9472A, J9473A, J8693A, J9311A)

  • 3-year, 4-hour onsite, 13x5 coverage for hardware (H4496E)
  • 3-year, 4-hour onsite, 24x7 coverage for hardware (H2893E)
  • 3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 SW phone support and SW updates (U6319E)
  • 3-year, 24x7 SW phone support, software updates (UE264E)
  • Installation with minimum configuration, system-based pricing (U4826E)
  • Installation with HP-provided configuration, system-based pricing (U4830E)
  • 4-year, 4-hour onsite, 13x5 coverage for hardware (UR884E)
  • 4-year, 4-hour onsite, 24x7 coverage for hardware (UR885E)
  • 4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR886E)
  • 4-year, 24x7 SW phone support, software updates (UR887E)
  • 5-year, 4-hour onsite, 13x5 coverage for hardware (UR888E)
  • 5-year, 4-hour onsite, 24x7 coverage for hardware (UR889E)
  • 5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR890E)
  • 5-year, 24x7 SW phone support, software updates (UR891E)
  • 3 Yr 6 hr Call-to-Repair Onsite (UW365E)
  • 4 Yr 6 hr Call-to-Repair Onsite (UW366E)
  • 5 Yr 6 hr Call-to-Repair Onsite (UW367E)

HP Networking Services

Services that add value to your business
The warranties on HP Networking products provide a robust foundation for ongoing network support, but many customers have advanced support needs. Today's enterprise businesses, regardless of their size, are under increasing pressure to reduce the cost and complexity of supporting their network infrastructures. Demand for new services from businesses and their end users is constantly increasing. HP offers an affordable, comprehensive portfolio of networking services for organizations of all sizes. HP has a unique services advantage you can benefit from, and HP is the only vendor in the IT industry that can provide integrated and consistent support for your entire technology infrastructure worldwide, including networking, servers and storage, and imaging and printing, as well as desktop and mobile computing, to help you grow your business with expert support that is affordable, personal, and scaled to your needs. HP Networking's implementation and design centers simplify your network planning, while HP Technology and Enterprise Services deliver choice and flexibility.

HP provides a full range of custom services to meet the end-to-end networking needs of our customers. HP Network Lifecycle Services form the core foundation of network consulting, assessments, planning, design, integration, deployment, and management. They are available as standalone services or can be crafted to deliver solutions across the services portfolio, spanning network performance, network security and risk management, global deployment, data center networking, wireless LAN/mobility, and Unified Communications and Collaboration.

Documentation:

PDF File
HP E3500 yl Switch Series Datasheet (.PDF)

 

HP ProCurve Products
HP ProCurve Switches
HP E3500-24 Switch #J9470A#ABA
List Price: $2,449.00
Our Price: $1,794.00
HP E3500-24-PoE Switch #J9471A#ABA
List Price: $3,099.00
Our Price: $2,270.00
HP E3500-24G-PoE yl Switch #J8692A#ABA
List Price: $3,999.00
Our Price: $2,512.00
HP E3500-24G-PoE+ yl Switch #J9310A#ABA
List Price: $3,899.00
Our Price: $2,856.00
HP E3500-48 Switch #J9472A#ABA
List Price: $4,099.00
Our Price: $3,003.00
HP E3500-48-PoE Switch #J9473A#ABA
List Price: $5,299.00
Our Price: $3,882.00
HP E3500-48G-PoE yl Switch #J8693A#ABA
List Price: $7,199.00
Our Price: $5,274.00
HP E3500-48G-PoE+ yl Switch #J9311A#ABA
List Price: $7,199.00
Our Price: $5,274.00
HP ProCurve Accessories
Modules
HP 10 GbE 2-port X2 / 2-port CX4 yl Module #J8694A
List Price: $3,899.00
Our Price: $2,856.00
HP 10 GbE 2-port SFP+/2-port CX4 yl Module #J9312A
List Price: $1,999.00
Our Price: $1,464.00
Transceivers
HP ProCurve 10-GbE X2-SC ER Optic #J8438A
List Price: $10,999.00
Our Price: $8,059.00
HP ProCurve 10-GbE X2-SC SR Optic #J8436A
List Price: $1,819.00
Our Price: $1,332.00
HP ProCurve 10-GbE X2-CX4 Transceiver #J8440C
List Price: $909.00
Our Price: $666.00
HP ProCurve 100-FX SFP-LC Transceiver #J9054B
List Price: $259.00
Our Price: $189.00
HP ProCurve 10-GbE X2-SC LR Optic #J8437A
List Price: $3,899.00
Our Price: $2,856.00
HP ProCurve 10-GbE X2-SC LRM Optic #J9144A
List Price: $1,899.00
Our Price: $1,391.00
HP ProCurve 100-BX-D SFP-LC Transceiver #J9099B
List Price: $459.00
Our Price: $336.00
HP ProCurve 100-BX-U SFP-LC Transceiver #J9100B
List Price: $459.00
Our Price: $336.00
HP ProCurve Gigabit-LH-LC Mini-GBIC #J4860C
List Price: $3,999.00
Our Price: $2,930.00
HP ProCurve Gigabit-SX-LC Mini-GBIC #J4858C
List Price: $419.00
Our Price: $307.00
HP ProCurve Gigabit-LX-LC Mini-GBIC #J4859C
List Price: $899.00
Our Price: $658.00
HP ProCurve Gigabit 1000Base-T Mini-GBIC #J8177C
List Price: $359.00
Our Price: $263.00
HP ProCurve 1000-BX-D SFP-LC Mini-GBIC #J9142B
List Price: $1,249.00
Our Price: $915.00
HP ProCurve 1000-BX-U SFP-LC Mini-GBIC #J9143B
List Price: $1,249.00
Our Price: $915.00
HP X132 10G SFP+ LC SR Transceiver #J9150A
List Price: $1,519.00
Our Price: $1,118.00
HP X132 10G SFP+ LC LR Transceiver #J9151A
List Price: $3,699.00
Our Price: $2,710.00
HP X132 10G SFP+ LC LRM Transceiver #J9152A
List Price: $1,599.00
Our Price: $1,171.00
HP X132 10G SFP+ LC ER Transceiver #J9153A
List Price: $8,999.00
Our Price: $6,593.00
Power Supply
HP E620 Redundant/External Power Supply #J8696A
List Price: $2,799.00
Our Price: $2,050.00
HP E630 Redundant and/or External Power Supply #J9443A
List Price: $1,799.00
Our Price: $1,318.00
Mounting Kit
HP X410 E-Series 1U Universal 4-Post Rack Mounting Kit #J9583A
Our Price: $129.00
License
HP E3500 Switch Premium License #J8993A
List Price: $1,999.00